Abstract

This paper reports the experimental results of a plasma opening switch (POS) that operates at hydrogen and carbon plasma regimes confirmed based on the conduction bipolar limit of the plasma species and the availability of plasma species during the conduction based on the density profiles. The generator is the compact capacitor bank developed using the synchronization of four field distortion spark gap switches. The plasma source is coaxial cable plasma guns characterized using the Faraday cup plasma diagnostic. The experimental results are compared with the time domain simulation code in which the POS is represented as the dynamic resistance governed by the physical equations of the bipolar model. The experiments and simulations are compared for inductive load and dynamic load of accelerating gap of 5 mm between the anode and cathode at the load end. From the results, POS can be operated based on the availability of plasma species with proper synchronized triggering between the plasma gun firing and generator firing that can operate at low and high values of currents.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.