Abstract

In the operation process of permanent magnet governor, the temperature rises due to eddy current loss, and demagnetization of permanent magnet occurs at high temperature. The numerical simulation of fluid flow field and temperature field was carried out with the method of computational fluid dynamics (CFD) and ANSYS-Fluent software. And then we improved the structure of permanent magnet governor on the basis of analysis of the flow field and temperature distribution. The result indicates that the flow of improved structure increases, and temperature drops 46.°C, fulfilling the desired temperature range of permanent magnet can bear, which provides a theory basis for the design of ventilation-cooling structure of permanent magnet governor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.