Abstract
Magnetoencephalography (MEG) conventionally operates within high-performance magnetic shields due to the extremely weak magnetic field signals from the measured objects and the narrow dynamic range of the magnetic sensors employed for detection. This limitation results in elevated equipment costs and restricted usage. Additionally, the information obtained from MEG is functional images, and to analyze from which part of the brain the signals are coming, it is necessary to capture morphological images separately. When MEG and morphological imaging devices are separate, despite their individual high measurement accuracies, discrepancies in positional information may arise. In response, we have developed a low-field magnetic resonance imaging system that incorporates scalar-mode optically pumped magnetometers with a wide dynamic range and exceptionally high measurement sensitivity as sensors for MEG. Operating at low magnetic fields eliminates the need for superconducting coils in magnetic resonance imaging and the high-performance magnetic shields essential for MEG, promising a substantial cost reduction compared to traditional approaches. We achieved a noise level of about 16.7pT/Hz1/2\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\usepackage{upgreek} \\setlength{\\oddsidemargin}{-69pt} \\begin{document}$${16.7}\\,\\hbox {pT/Hz}^{1/2}$$\\end{document} with a single channel magnetometer, and reached a noise level of 367fT/cm/Hz1/2\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\usepackage{upgreek} \\setlength{\\oddsidemargin}{-69pt} \\begin{document}$${367}\\,\\hbox {fT/cm/Hz}^{1/2}$$\\end{document} with a baseline of 1 cm through differential measurements. We employed this system to conduct sequential OPM-based magnetic field measurements and MRI imaging, successfully demonstrating the compatibility of high OPM sensitivity with clear MRI acquisition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.