Abstract

The aim of the present study was to evaluate whether estimation of lactobacilli was possible with simplified saliva sampling methods. Dentocult® LB (Orion Diagnostica AB, Trosa, Sweden) was used to estimate the number of lactobacilli in saliva sampled by 3 different methods from 96 individuals: (i) Collecting and pouring stimulated saliva over a Dentocult® dip-slide; (ii) direct licking of the Dentocult® LB dip-slide; (iii) contaminating a wooden spatula with saliva and pressing against the Dentocult® dip-slide. The first method was in accordance with the manufacturer's instructions and selected as the 'gold standard'; the other 2 methods were compared with this result. The 2 simplified methods for estimating levels of lactobacilli in saliva showed good reliability and specificity. Sensitivity, defined as the ability to detect individuals with a high number of lactabacilli in saliva, was sufficient for the licking method (85%), but significantly reduced for the wooden spatula method (52%).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.