Abstract

Finite control set model predictive control evaluates a predefined cost function for each switching state of power converter. In addition to reference tracking term, cost function can include a term for switching frequency reduction. Small value for the weighting factor of switching reduction term cannot reduce switching frequency effectively and the great value results in reference tracking failure and increase current ripple. In this study a variable weighting factor based on current ripple is obtained and applied to the cost function. The value of weighting factor changes with the position and magnitude of reference voltage. Simulation and experimental results verify the effectiveness of proposed method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.