Abstract
A simplified model is proposed dealing with a heat transfer crisis during forced flow of water in tubes. The formula for the critical heat flow is obtained. The verification showed that this formula with a single empirical coefficient embraces 4745 experimental values of critical heat flows at a mean square error of 0.0691 in a wide range of parametric variations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.