Abstract

In this paper, an analysis of the interaction between the switching ripple filter components of a matrix converter-based drive and the components of a 0.4-kV electrical grid is presented. Based on the analysis, we propose a simplification of the conventional LCR filter. An inductance of the power grid transformer windings and an impedance of the power distribution lines could be considered as a filter component. Stemming from the above, a simplification of the filter topology is proposed. Only the capacitance component is necessary for realizing a conventional LCR filter. The effectiveness of this simplification is demonstrated through calculations, simulations performed in MATLAB/Simulink, and experimental results on a laboratory prototype.