Abstract
We describe a needle insertion technique for graft insertion in Descemet-stripping (automated) endothelial keratoplasty (DSEK/DSAEK). A folded donor posterior corneal disk is inserted through a 5.0 mm scleral tunnel incision over a plastic glide using a 30-gauge needle. The technique enables safe and easy graft insertion without vertical or horizontal compression of the donor tissue, causing minimal trauma to the donor endothelium and/or host structures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.