Abstract

Cellular and brain metabolism of dopamine can be correlated with a number of neurodegenerative disorders, our study was to explore a simple and efficient method to detect dopamine in real samples. A new quantum dots (CdTe QDs) could be prepared using the hydrothermal method, the electrochemical biosensor was established by dropping CdTe QDs on the surface of glassy carbon electrode (GCE). The CdTe QDs/GCE exhibited the excellent electrochemical catalytic activity toward dopamine (DA) with good stability and high sensitivity in presence of interfering substances. The detection limit of DA was calculated by differential pulse voltammetry (DPV) as low as 0.3μmol L-1 with a linear dynamic range of 1μmol L-1 to 400μmol L-1 . In this paper, the proposed electrochemical biosensor could be effectively used for the direct and rapid detection of DA in human serum and urine samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.