Abstract

A simple, stable and sensitive electrogenerated chemiluminescence (ECL) detector was developed. It was based on tris(2,2-bipyridyl)ruthenium(II) (Ru(bpy) 3 2+) immobilized on the surface of a Pt wire with Nepem-105D ion exchange solution. The detector was prepared by inserting a Pt wire with immobilized Ru(bpy) 3 2+ (working electrode) into a capillary tube, followed by inserting another Pt wire (counter electrode) in this tube and sealing. ECL behavior was investigated using ofloxacin as an analyte. Under optimal conditions, stable ECL intensity was obtained. This detector has been used in HPLC-ECL for the determination of multiple target fluoroquinolone residues in milk. There is no post column reagent addition, which would dilute the analytes, potentially leading to chromatographic band-broadening. The system is very simple with low dead volume, low baseline and background noise, together with high sensitivity and stability. The as-prepared ECL detector, when was used for the determination of ofloxacin, pefloxacin, enrofloxacin and difloxacin in milk, demonstrated adequate sensitivity to allow quantification of trace FQ levels in commercial milk samples. One or more of the target FQ analytes were present at levels above the LOD of the new ECL detector in each and every one of the 22 milk samples analysed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.