Abstract

We present an easy-to-implement and low-cost setup for the precise measurement of the period chirp of diffraction gratings offering a resolution of 15 pm and reasonable scan speeds of 2 seconds per measurement point. The principle of the measurement is illustrated on the example of two different pulse compression gratings, one fabricated by laser interference lithography (LIL) and the other by scanning beam interference lithography (SBIL). A period chirp of 0.22 pm/mm2 at a nominal period of 610 nm was measured for the grating fabricated with LIL, whereas no chirp was observed for the grating fabricated by SBIL, which had a nominal period of 586.2 nm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.