Previous methods using low- or high-pressure liquid chromatography and UV absorbance for quantitation of arabinosides in plasma can practically detect only >/=200 ng of adenine arabinoside and >/=100 ng of hypoxanthine arabinoside per ml, and they require expensive equipment and expert technical assistance. We describe in this report a simple quantitative microbioassay for arabinosides in human plasma based on their ability to inhibit the cytopathic effect of vaccinia virus in an adenosine deaminase-free cell culture system. Using prior separation of nucleosides in plasma by thin-layer chromatography, followed by the microbioassay, we quantitated adenine arabinoside with a sensitivity of approximately 4 ng/ml and hypoxanthine arabinoside at approximately 625 ng/ml. This assay method is simple, sensitive, and reproducible, requires small plasma samples, measures biological activity, and is adaptable to routine use. It is an important tool for evaluating the pharmacology of adenine arabinoside and Ara-AMP in patients in current clinical trials.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.