Abstract

Fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to probe the molecular environment of fluorophores. The analysis of FLIM images is usually performed with time consuming fitting methods. For accelerating this analysis, sophisticated deep learning architectures based on convolutional neural networks have been developed for restrained lifetime ranges but they require long training time. In this work, we present a simple neural network formed only with fully connected layers able to analyze fluorescence lifetime images. It is based on the reduction of high dimensional fluorescence intensity temporal decays into four parameters which are the phasor coordinates, the mean and amplitude-weighted lifetimes. This network called Phasor-Net has been applied for a time domain FLIM system excited with an 80 MHz laser repetition frequency, with negligible jitter and afterpulsing. Due to the restricted time interval of 12.5 ns, the training range of the lifetimes was limited between 0.2 and 3.0 ns; and the total photon number was lower than 106, as encountered in live cell imaging. From simulated biexponential decays, we demonstrate that Phasor-Net is more precise and less biased than standard fitting methods. We demonstrate also that this simple architecture gives almost comparable performance than those obtained from more sophisticated networks but with a faster training process (15 min instead of 30 min). We finally apply successfully our method to determine biexponential decays parameters for FLIM experiments in living cells expressing EGFP linked to mCherry and fused to a plasma membrane protein.

Highlights

  • Fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to probe the molecular environment of fluorophores

  • We demonstrate that Phasor-Net is more precise and less biased than standard fitting approaches for realistic signal to noise ratio (SNR) simulated data that could be encountered in fluorescence resonance energy transfer (FRET) experiments

  • When we increase the number of photons per pixel up to 20,000 by applying a binning factor of 10, we reduce notably the absolute errors of lifetimes; they become 0.16 ns for τ1, 0.07 ns for τ2 and 0.01 ns for < τ > but this strong spatial filtering severely degrades FLIM images

Read more

Summary

Introduction

Fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to probe the molecular environment of fluorophores. In comparison with FLI-Net, our “phasor-based” neural network is largely dispersed (we report an interquartile range of 0.2 for a1 and 0.8 ns for the lifetimes) but Phasor-Net gives almost unbiased results.

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.