Abstract

BackgroundFollowing each cycle of peptide receptor radionuclide therapy (PRRT), absorbed doses by tumors and normal organs are typically calculated from three quantitative single-photon emission computed tomography (SPECT)/computed tomography (CT) studies acquired at t1 = 24 h, t2 = 96 h, t3 = 168 h after the first cycle of treatment and from a single study at t1 after the subsequent cycles. In the present study, we have assessed the feasibility of a single SPECT/CT study after each PRRT cycle using a trained multiple linear regression (MLR) model for absorbed dose calculation and have evaluated its impact on patient management. Quantitative [177Lu]-DOTA-TATE SPECT/CT data after PRRT of seventy-two consecutive metastatic neuroendocrine tumors patients were retrospectively evaluated. A set of 40 consecutive studies was used to train the MLR model. The two independent variables of the model included the time of imaging after administration of the treatment and the radiopharmaceutical activity concentration in a given organ/tumor. The dependent variable was the dose absorbed by the organ/tumor obtained with the standard protocol. For bone marrow dosimetry, the independent variables included the time of imaging, and the blood and remainder of the body activity concentration. The model was evaluated in 32 consecutive patients. Absorbed doses were assessed for kidneys, bone marrow, liver, spleen and tumor sites.ResultsThere was no difference in management decisions, whether PRRT can be safely continued or not because unsafe absorbed dose to risk organs between the standard and the MLR model-based protocol using a single SPECT/CT study performed at t3 = 168 h after the first cycle and at t1 = 24 h after the subsequent cycles. Cumulative absorbed doses were obtained with mean relative differences of − 0.5% ± 5.4%, 1.6% ± 15.1%, − 6.2% ± 7.3%, − 5.5% ± 5.8% and 2.9% ± 12.7% for kidneys, bone marrow, liver, spleen and tumors, respectively (Pearson’s r correlation coefficient 0.99, 0.91, 0.99, 0.99 and 0.97, respectively).ConclusionDosimetry calculations using a MLR model with a single SPECT/CT study are in good agreement with the standard protocol, while avoiding the use of dosimetry software and enabling improved patient comfort and reduced scanner and staff time.

Highlights

  • Following each cycle of peptide receptor radionuclide therapy (PRRT), absorbed doses by tumors and normal organs are typically calculated from three quantitative single-photon emission computed tomography (SPECT)/computed tomography (CT) studies acquired at t1 = 24 h, t2 = 96 h, t3 = 168 h after the first cycle of treatment and from a single study at t1 after the subsequent cycles

  • Model training The time of imaging and the activity concentrations included in the independent variables of Eqs. (4) and (7) were expressed in [h] and [mCi/cc], respectively

  • Regression coefficients Bone marrow (BM),BM, BM,RM, β0,BM, β1,BM and β2,BM and rt2rain using Eq (7) for bone marrow are presented when using independent data at tf = t1 or t3 or both. These results show that the multiple linear regression (MLR) model fit is improved when using a single SPECT/CT study at t2 for organs and tumor absorbed dose estimation

Read more

Summary

Introduction

Following each cycle of peptide receptor radionuclide therapy (PRRT), absorbed doses by tumors and normal organs are typically calculated from three quantitative single-photon emission computed tomography (SPECT)/computed tomography (CT) studies acquired at t1 = 24 h, t2 = 96 h, t3 = 168 h after the first cycle of treatment and from a single study at t1 after the subsequent cycles. We have assessed the feasibility of a single SPECT/CT study after each PRRT cycle using a trained multiple linear regression (MLR) model for absorbed dose calculation and have evaluated its impact on patient management. The two independent variables of the model included the time of imaging after administration of the treatment and the radiopharmaceutical activity concentration in a given organ/tumor. The PRRT treatment series is stopped if the cumulative dose absorbed by kidneys and bone marrow is expected to exceed 25 Gy and 2 Gy, respectively [13, 14]

Objectives
Methods
Results
Discussion
Conclusion
Full Text