Flash points (TFP) of organic compounds are calculated from their flash point numbers, NFP, with the relationship TFP = 23.369NFP2/3 + 20.010NFP1/3 + 31.901. In turn, the NFP values can be predicted from boiling point numbers (YBP) and functional group counts with the equation NFP = 0.974YBP + ∑i niGi + 0.095 where Gi is a functional group-specific contribution to the value of NFP and ni is the number of such functional groups in the structure. For a data set consisting of 1000 diverse organic compounds, the average absolute deviation between reported and predicted flash points was less than 2.5 K.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.