Abstract

ABSTRACTA topology optimized rigid triangular FE macro-model with non-linear homogenized interfaces for the pushover analysis of in plane loaded masonry is presented. The shape of the mesh and the position of the interfaces is evaluated through a topology optimization approach that detects the main compressive stress fluxes in the structure. Different values of the horizontal action are considered to derive an adaptive mesh or an optimal discretization that is suitable for multiple loads. Masonry properties are calibrated by means of a homogenization approach in the nonlinear range. To tackle elastic and inelastic deformations, interfaces are assumed to behave as elasto-plastic with softening in both tension and compression, with orthotropic behavior. The two-step procedure competes favorably with classic equivalent frame approaches because it does not require a-priori assumptions on the mesh and on the length of the rigid offsets. An example of technical relevance is discussed, relying into a multi-story masonry wall loaded up to failure.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call