Abstract

A simple method was developed for the determination of captan and chlorothalonil (TPN) in air. Air was taken through two round shaped activated carbon fiber papers with diameter of 47 mm (Toyobo KF Paper P-175) using an automated sequential air sampler (Tokyo Dylec 10-line Global Sampler GS-10D) at 10 to 20 l min-1 for 3 h. Each the sampled paper was extracted ultrasonically with 3 ml of xylene for 10 min followed by centrifugation at 3000 rpm for 10 min. An aliquot of the supernatant was analyzed by GC equipped with ECD (63Ni) on a fused-silica capillary column coated with methyl silicone (df=2.65 μm, 0.53 mm i.d.×10 m). The collection efficiencies and recoveries of captan and TPN were quantitative; the minimum detectable concentrations were 4 ng m-3 for captan and TPN. The fungicides were stable on the paper for a week at -20°C. This method was applied to determine captan and TPN in air near golf courses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.