Abstract

A simple method for the determination of paracetamol (acetaminophen) with sodium 1,2-naphthoquinone-4-sulphonate (NQS) in alkaline medium using flow injection analysis (FIA) was developed and validated. The effect of variables such as flow rate, NQS concentration, reaction coil length, NaOH concentration, and detection wavelength were studied. Linear response was found over the concentration range 3–35 mg L−1 (r2 = 0.9995), the relative standard deviation from replicate injections (n = 9) of 20 mg L−1 of paracetamol was 0.89%. A sampling rate of 82 samples h−1 was obtained. The method was applied for the determination of paracetamol in pharmaceutical tablets, and results have been compared with those obtained by the official method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.