Abstract

There is a recent interest in nonsurgical correction of superior sinus venosus defects. Patient selection is currently based on advanced imaging and printing technologies. Simple clinical tools to select patients will expand its applicability in developing countries. Defects caudally extending toward the oval fossa and right upper pulmonary veins draining beyond the cavoatrial junction on transesophageal echocardiography were excluded. Balloon interrogation of cavoatrial junction confirmed complete occlusion of the defect with unobstructed pulmonary venous drainage to left atrium. Single long covered stents or overlapping covered stents were used to exclude sinus venosus defects. Closure of left-to-right interatrial shunt without causing pulmonary vein occlusion was confirmed on follow-up imaging. Forty-four patients selected after transesophageal echocardiography underwent balloon interrogation with monitoring of right upper pulmonary vein. Eighteen out of 44 patients were ineligible. Twenty-four eligible patients with closure of left-to-right interatrial shunt without pulmonary vein occlusion underwent covered stent exclusion using single long stents in 15 and overlapping stents in the rest, while 2 patients are awaiting the procedure. Four patients aged 6 to 16 years received stents that were 18 mm or larger. Three patients had stent embolization that required surgical correction in 2 but in the last patient was managed nonsurgically with an overlapping covered stent with good final outcomes. Procedure was successful in 22 patients. At a median follow-up of 20 months (range, 3-54 months), there were no adverse events. Follow-up imaging showed trivial left-to-right shunt in 4 and unobstructed pulmonary veins in all patients. Transesophageal echocardiography and balloon interrogation identified 60% of the patients with sinus venosus defects to be eligible for catheter closure. Overlapping stents are an alternative to custom-made long stents. Transesophageal echocardiography confirms procedural success on follow-up. Advanced imaging and printing technologies are not essential for successful outcomes and thus simple tests increase the feasibility in developing countries.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.