Abstract

In this work, a simple method, namely, tandem dispersive liquid-liquid microextraction, with a high sample clean-up is applied for the rapid determination of the antidementia drugs rivastigmine and donepezil in wastewater and human plasma samples. This method, which is based on two consecutive dispersive microextractions, is performed in 7min. In the method, using a fast back-extraction step, the applicability of the dispersive microextraction methods in complicated matrixes is conveniently improved. This step can be performed in less than 2min, and very simple tools are required for this purpose. To achieve the best extraction efficiency, optimization of the variables affecting the method was carried out. Under the optimized experimental conditions, the relative standard deviations for the method were in the range of 6.9-8.7%. The calibration curves were obtained in the range of 2-1100ng/mL with good correlation coefficients, higher than 0.995, and the limits of detection ranged between 0.5 and 1.0ng/mL.