Abstract

Food, especially animal origin food is the main source of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), and dioxin-like polychlorinated biphenyls (dl-PCBs) for human exposure. So, a simple, rapid and cheap bioassay method is needed for determination of dioxins in food samples. In this study, we used a new highly sensitive reporter cell line to determine the concentration of dioxins in 33 fish and seafood samples. The samples were extracted by shaking with water/isopropanol (1:1 v/v) and hexane and cleaned-up by a multi layered silica gel column and an alumina column, then analyzed using CBG 2.8D cell line. We compared the results obtained from the CBG 2.8D cell assay to those obtained from conventional High-Resolution Gas Chromatography–High Resolution Mass Spectrometry (HRGC–HRMS) analysis. Good correlations were observed between these two methods (r2=0.93). While the slope of regression line was 1.76, the bioanalytical equivalent (BEQ) values were 1.76 folds higher than WHO-TEQ values and the conversion coefficient was 0.568 (the reciprocal of 1.76). In conclusion, CBG 2.8D cell assay was an applicable method to determine dioxins levels in fish and sea food samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.