Abstract

A method for determining the fibre volume fraction, V f and the void fraction, V g, in a metal matrix composite (MMC) material is described. These quantities are determined from specimen weight measurements in air and in a liquid using a laboratory balance. For a material without voids, V f can be determined with an uncertainty less than 0.5% with a balance precision of 0.01%. By making the same measurements before and after etching away the matrix, using the same balance precision, V f and V g can be determined to an uncertainty of about 3 and 6%, respectively. It is also shown theoretically that by indenting a specimen containing no fibres and only a uniform distribution of small voids, the void fraction can also be determined from weight measurements before and after indentation.