Abstract
From 2009 to 2012, 14 failure high strength bolts were found in Chaotianmen Bridge,and 11 bolts were collected on site, of which 8 bolts were pitted and rusted. The chemical composition, metallographic structure, hardness and other mechanical properties of these 11 bolts were analyzed and tested to explore the reasons for fracture failure of high strength bolts. The results show that six failure high strength bolts` HRC values are of 40, 40.5 and 43 (4 bolts), which does not meet the technical requirement of GB/T1231-2006, and the unqualified rate accounts for 54.5%. Tempered martensite, which belongs to brittle structure, was detected in metallographic structure in samples with unqualified hardness. The failure of high strength bolts is not only related to the unqualified metallographic structure, but also related to the construction processs, operating environment and other aspects. Especially the influence of environmental corrosion on the quality, micro-structure and mechanical properties of high strength bolts should be paid more attention by bridge managers. It is necessary to further explore and clarify the influence of environmental factors on the corrosion fracture of high strength bolts and its mechanism, so as to provide a basis for the measures taken to prevent the breakage of high strength bolts.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.