Abstract

A fast, real-time and similarity analysis-based diagnosis method for open-circuit faults in three-phase voltage-source inverters is proposed. The proposed method is based on the mixed logical dynamic (MLD) model of the PMSM drive system to simulate three-phase currents under different faulty conditions, and the Pearson correlation coefficients (PCCs) are used to measure the similarity between the simulated fault types and the actual one, then the fault detection and isolation can be achieved according to the characteristics of PCCs under different faulty conditions. The proposed method only needs to use the current sensors existing in the closed-loop system to measure the currents for fault diagnosis, and can detect the fault within one current fundamental wave period. Simulation results verify the effectiveness of the proposed method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.