Abstract

Commercial radio-photoluminescence (RPL) glass dosimeters generally use Ag single-doped phosphate glass as a single-wavelength sensor. Now, a novel type of Ag–Nd-codoped phosphate glass has been developed, which can be applied to dual-wavelength or multi-wavelength RPL sensors, and can thus improve the accuracy and stability of RPL dosimeters. An anhydrous 99.5 (0.7LiPO3–0.3Al (PO3)3) −0.25Ag2O–0.25Nd2O3 glass was prepared and irradiated at different doses, and then the absorption, fluorescence, infrared transmission spectra, as well as fluorescence lifetimes were tested and analyzed. The results show that there is an energy transfer between the Ag defect center and Nd3+ ions, and the transfer efficiency using 380 nm excitation is greater than that using 310 nm excitation. Aside from the 650 nm fluorescence of the Ag defect center, strong 882 nm and 1054 nm fluorescences of Nd ions are exhibited. It is possible that these fluorescences would allow the developed Ag–Nd-codoped phosphate glass to be applied to new RPL glass sensors and dosimeters.