Abstract
Ni plating of Ag-In-Cd control rod alloys to a thickness of 0.005 to 0.05 in. is found to yield a durable coating that does not undercut. The use of Ag-In-Cd control rods in the Yankee power reactor is reviewed, with attention to their endurance, their lifetime with respect to core lifetime, their worth as a function of irradiation dose, their surface absorption as a function of reactor energy density, and the dependence of reactivity on the total control rod surface area/reactor volume ratio. (T.F.H.)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.