Abstract

A 51-year-old woman underwent endoscopic nasal polypectomy and ethmoidectomy with accidental entry into the right orbit causing enophthalmos and transection of the medial rectus muscle (MR). The repair of a fracture and of a damaged MR is technically challenging, particularly when large portions of bone and muscle are missing. We report a rare case of repair of the bony defect with an implant and reattachment of the MR with a silicone retina band, through a combined transcaruncular and transconjunctival approach. Postoperatively, the patient had residual enophthalmos and strabismus; further surgical options are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.