Abstract

A silicone rubber-coated Mach–Zehnder interferometer (MZI) is proposed and applied to temperature measurement. The MZI is fabricated by splicing single mode fiber between a short section of no-core fiber (NCF) and the ultra-abrupt taper region. The sensing length of MZI is coated with liquid silicone rubber to enhance the temperature sensitivity. Here, NCF is used to excite the higher order cladding mode, the ultra-abrupt taper region acts as a optical fiber coupler, and the silicone rubber coating on sensing length is used as solid cladding material instead of liquid. The enhancement of the sensitivity of a device is due to the high refractive index (1.42) and thermo-optic coefficient (−1.4×10−4/°C) of silicone rubber as compared to liquid cladding temperature sensors. The experiment was performed for both coated and uncoated MZI and the results were compared. The MZI exhibits a high temperature sensitivity of 253.75 and 121.26 pm/°C for coated and uncoated sensing probes, respectively, in the temperature range from 30°C to 75°C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.