Abstract

By examining the breaking strength and gap formation of tendon graft junction sites covered with pseudosheath at various times of immobilization, no significant increase was found compared to junction sites not covered by the pseudosheath. The optimum time for immobilization following tendon grafting is between 4 and 5 weeks in the chicken. Total coverage of the junction sites by pseudosheath did not affect gap formation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.