Abstract

In the paper safety analysis of interface between electronic type of automatic level crossing device (LC) and relay based device of automatic block system (AB) is conducted for the purpose of indentifying the influence of their joint work on traffic safety. The analysis encompasses all potential failure cases in communication between observed signal-safety devices of AB and LC. Based on the results of the analysis it has been proved that the observed interface meets the safety criteria for application in railway transport, because if any failure occurs the respective signal-safety devices will always shift to a higher level of traffic safety, which is why it is not compromised.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.