Experiments are reported to evaluate the photomultiplier tube (PMT) used in Rayleigh/aerosol lidar system. The response of PMT to pulsed light signal of different intensity have been investigated. A green light emitting diode driven by a function generator is used as a pulsed light source. In this article we report the response of PMT used in the system to the pulsed source generating light signal comparable to the signal received by the PMT during laser firing in to the atmosphere. The signal induced noise (SIN) is found to be a linear combination of two exponentially decaying functions. Other results of SIN are presented.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.