Abstract

This paper presents a systematic development of a unified signal flow graph model for an interleaved DC–DC parallel converter system operating in continuous current mode. This signal flow graph approach provides a means to translate directly the switching converter to its graphic model, from which the steady-state and dynamic behaviour of the converter can be studied easily. The development of a unified signal flow graph is explained for a three-cell interleaved parallel converter system. Derivation of large-signal, small-signal and steady-state models from a unified signal flow graph is demonstrated by considering a two-cell interleaved converter system operating in complementary activation mode. Converter performance expressions such as steady-state voltage gain, efficiency expressions and small-signal characteristic transfer functions are also derived. A large-signal model was programmed in a TUTSIM simulator, and the large-signal responses against supply and load disturbances were predicted. Signal flow graph analysis results are validated with PSIM simulations. Experimental observations are provided to validate the signal flow graph modelling method. Further, the mathematical models obtained from the signal flow graph modelling are in agreement with those obtained from the state-space averaging technique.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call