Abstract
Low‐impedance acoustic baffles are often used to shield hydrophones from unwanted noise. However, when the hydrophones must be located close to such low‐impedance surfaces, the resulting loss in signal sensitivity can lead to a decrease in signal‐to‐noise ratio. Several techniques have been devised to maintain the signal sensitivity of hydrophones in these instances. The theoretical performance characteristics of several such signal conditioning techniques have been examined. Results are presented for the following types: (1) mass layer, (2) hydrophone standoff, (3) a single homogeneous absorptive layer, (4) combinations of mass layers, standoff, and tuned compliant layers, and (5) superdirective hydrophones. In every case the low‐frequency signal conditioning performance is determined by the total mass of the signal conditioning treatment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.