Abstract
This paper presents a signal based approach to detect PWM inverter faults and motor unbalances in electrical drives. A diagnostic system which uses the control variables of the drive and the current measurements is presented. It is based on frequency analysis and on the energetic characterization of these variables in the PWM frequency domain. These method very simple to implement in real time have been successfully applied to an experimental system.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.