Abstract

Children younger than 1 year of age are unique in their physiology and comorbidities. Reports in the literature suggest that the risk factors for shunt infection may be different in this population compared with older children. Importantly, these infants often have other congenital malformations requiring various surgical interventions, which impose an additional risk of infection. In the 3-year period between 2008 and 2010, 270 patients underwent initial CSF shunt placement during the 1st year of life. Clinical characteristics, hospital course, and shunt infections were prospectively recorded in the practice and hospital electronic medical record. Special attention was given to types and timing of other invasive procedures and their relationship with shunt infection. The average gestational age was 33.6 weeks, and the average birth weight was 2333 g. The average weight at the time of shunt insertion was 4281 g. Prior to shunt insertion, 120 patients underwent 148 surgical procedures, including ventricular access device insertion (n = 63), myelomeningocele closure (n = 37), and cardiac procedures (n = 11), among others. In the 12-month period after shunt insertion, 121 of the 270 patients underwent 135 surgical procedures, which included 79 CSF shunt revisions. Shunt infection occurred in 22 patients, and organisms were identified in 20 cases. Univariate analysis showed that of the very prematurely born infants (gestational age < 30 weeks), those who underwent preshunt cardiac surgery and any surgical procedures within 30 days after the shunt insertion were at a greater risk of shunt infection. In multivariate analysis, preshunt cardiac surgery and surgical procedures within 30 days postshunt placement were significant risk factors independent of gestational age, birth weight, and history of shunt revisions. The results of this study suggest that surgical procedures within 30 days after shunt insertion and preshunt cardiac surgery are associated with a greater risk of shunt infection in children in whom these devices were inserted during the 1st year of life.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.