Background For thoracolumbar burst fractures, traditional four-screw (one above and one below) short-segment instrumentation is popular and has a high failure rate. Additional augmentation at the fractured vertebrae is believed to reduce surgical failure. The purpose of this study was to examine the clinical and radiographic results of patients who underwent short-segment posterior instrumentation with augmentation by screws and bone substitutes at the fractured vertebrae and to compare these data to those of patients who underwent long-segment instrumentation for thoracolumbar burst fractures. Methods The study group had twenty patients who underwent short-segment instrumentation with additional augmentation by two screws and bone substitutes at the fractured vertebrae. The control group contained twenty-two patients who underwent eight-screw long instrumentation without vertebra augmentation. Local kyphosis and the anterior body height of the fractured vertebrae were measured. The severity of the fractured vertebrae was evaluated with the load sharing classification (LSC). Any implant failure or loss of correction >10° at the final follow-up was defined as surgical failure. Results Both groups had similar distributions in terms of age, sex, the injured level, and the mechanism of injury before operation. During the operation, the study group had significantly less blood loss (136.0 vs. 363.6 ml, p=0.001) and required shorter operating times (146.8 vs. 157.5 minutes, p=0.112) than the control group. Immediately after surgery, the study group had better correction of the local kyphosis angle (13.4° vs. 11.9°, p=0.212) and restoration of the anterior height (34.7% vs. 31.0%, p=0.326) than the control group. At the final follow-up, no patients in the study group and only one patient in the control group experienced surgical failure. Conclusions Patients with thoracolumbar burst fractures who received six-screw short-segment posterior fixators with augmentation at the level of the fractured vertebrae via injectable artificial bone substitute achieved satisfactory clinical and radiographic results, and this method could replace long-segment instrumentation methods used in unstable thoracolumbar burst fractures.

Highlights

  • Spine fractures commonly occur in the thoracolumbar region, and burst fractures account for 30% to 60% of thoracolumbar fractures [1, 2]

  • The first author performed all surgeries with short-segment instrumentation plus fractured vertebra augmentation with screws and bone substitute; the second author performed most surgeries with traditional eightscrew long instrumentation in patients. e fees associated with injectable artificial bone substitutes are not covered by National Health Insurance in our country; this artificial bone substitute was used as long as we had obtained the patient’s consent

  • Twenty patients were treated with six-screw shortsegment instrumentations and bone substitute augmentation at the fractured vertebrae (Figure 1)

Read more

Summary

Introduction

Spine fractures commonly occur in the thoracolumbar region, and burst fractures account for 30% to 60% of thoracolumbar fractures [1, 2]. Traditional four-screw (one above and one below) short-segment instrumentation is popular and has a high failure rate. E purpose of this study was to examine the clinical and radiographic results of patients who underwent short-segment posterior instrumentation with augmentation by screws and bone substitutes at the fractured vertebrae and to compare these data to those of patients who underwent long-segment instrumentation for thoracolumbar burst fractures. E study group had twenty patients who underwent short-segment instrumentation with additional augmentation by two screws and bone substitutes at the fractured vertebrae. Patients with thoracolumbar burst fractures who received six-screw short-segment posterior fixators with augmentation at the level of the fractured vertebrae via injectable artificial bone substitute achieved satisfactory clinical and radiographic results, and this method could replace long-segment instrumentation methods used in unstable thoracolumbar burst fractures

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call