Abstract
Abstract Funding Acknowledgements Type of funding sources: Private company. Main funding source(s): Study grant by EPD Solutions, Philips, Netherlands Background The occlusion tool was recently introduced for KODEX-EPD which is a novel dielectric high-resolution cardiac imaging system. The occlusion tool provides information about level of pulmonary vein occlusion by the cryoballoon (CB) in CB-based pulmonary vein isolation (PVI) ablation procedures for atrial fibrillation (AF). Purpose Assess effects of the introduction of the occlusion tool on procedural parameters during CB-PVI such as feasibility, acute efficacy and periprocedural safety of KODEX-EPD in different software versions. Methods and Results 173 consecutive patients (60/173 (35%) paroxysmal AF, 64±12 years, 66/173 (38%) female) underwent CB-PVI with EPD imaging between 08/2019 and 10/2021. 38/173 (22%) of all patients were treated using software version 1.4.6, 33/173 (19%) patients with version 1.4.6a, 41/173 (24%) patients with version 1.4.7 and 61/173 (35%) patients with the latest version 1.4.8. Acute PVI was achieved in all patients. No major periprocedural complications were documented. Software version showed significant effects on procedure duration, fluoroscopy duration and dose area product in ANOVA testing (Figure 1A-C). The largest effect in post-hoc testing was observed for fluoroscopy duration (Figure 1B). Tobit regressions were fitted to model effects of software version on the censored variable contrast volume. All software versions predicted used contrast volume (p<0.00748, Figure 1D). Modelling only effects of procedure date on contrast volume was less accurate than for software version (r²=0.057, p for procedure date = 0.0031) and also a Likelihood-Ratio-Test between different regression models underlined significant effects of software version (p<0.0001). Conclusion CB-based PVI in combination with its PV-occlusion tool is feasible and safe. The present data strongly suggests a steady positive development of the novel wide-band dielectric imaging and mapping system towards a fluoroscopy- and dye-reduced CB-based AF-ablation. Software versions were introduced sequentially. Therefore time (procedure date) needs to be considered as the most relevant confounder of the described results (e.g. due to a learning curve using the system). However, differentiated statistical testing could show that the results are mainly explained by software version and only much weaker by procedure date.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.