A real-time high dynamic range (HDR) imaging and display method based on correlated double sampling is proposed for short-wave infrared (SWIR) cameras in order to effectively improve its range of brightness and contrast, as well as to obtain more image details. The method utilizes the correlated double sampling technique of the SWIR detector to extend the 14-bit raw image into a 16-bit HDR image and achieve 4 times the HDR imaging. Subsequently, a dynamic range compression process, including logarithmic mapping and histogram equalization, is performed for the 16-bit HDR image to be mapped to an 8-bit display. Finally, the experimental results show that the method can enrich the details of SWIR images under the premise of ensuring real-time imaging.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.