Abstract

Batteries in energy storage systems are exposed to electrical noise, such as alternating current (AC) harmonics. While there have been many studies investigating whether Lithium-ion batteries are affected by AC harmonics, such studies on Nickel Metal Hydride (NiMH) batteries are scarce. In this study a 10 Ah, 12 V NiMH battery was tested with three different harmonic current frequency overlays during a single charge/discharge cycle: 50 Hz, 100 Hz, and 1000 Hz. No effect on battery internal temperature or gas pressure was found, indicating that NiMH battery aging is not affected by the tested harmonic AC frequencies. This can reduce the cost of energy storage systems, as no extra filters are needed to safeguard the batteries. Instead, the capacitive properties of the batteries give the possibility to use the battery bank itself as a high pass filter, further reducing system complexity and cost.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.