The microscopical diagnosis of infectious diseases is an essential medical laboratory service in resource-poor countries. We conducted an external quality assessment (EQA) of peripheral laboratories in southern Ethiopia using a panel of 20 ready-prepared sputum and blood smears containing either no pathogens or locally common pathogens. Microscopists also undertook a colour discrimination test (Farnsworth-Munsell 100 hue test). Twenty microscopists from 10 health centres participated. Their microscopy results were compared with that of the EQA controllers. Their Kappa indices of agreement ranged from 0.1 to 0.89 (mean+/-SD: 0.58+/-0.21). Kappa values were analysed according to microscopists' colour discrimination ability. The Kappa indices for the correct reading of diagnostic smears were associated with the colour vision ability of the technicians. Our results suggest that routine quality improvement activities may not achieve their desired effect if the colour discrimination abilities of technicians are not considered.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.