Abstract

This report discusses the vibration and shock testing of a Gifford-McMahon cycle refrigerator. The system tested was a KelCool™ Model UCH 130 Cryogenic Helium Refrigerator with a modified second stage regenerator. The system was subjected to vibration tests in accordance with MIL-STD-167-1 and shock tests in accordance with MIL-S-901D. The system passed both the vibration and shock tests without any visible signs of damage. There was, however, some performance degradation at the second stage of the refrigerator which raised the minimum temperature by nearly 0.5K while the cooler was being vibrated transverse to its vertical axis. It is not apparent whether this is effect is strictly due to vibration or whether it is caused in part by the second stage displacer seal operating poorly in conjunction with the vibration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.