Abstract
This paper reports on a radiation shielding analysis performed on the Confinement Physics Research Facility (CPRF) under construction at Los Alamos National Laboratory. A reversed-field pinch device, the ZTH, was examined in an effort to obtain an estimate of the spatial distribution of the dose seen by both personnel and electronic components. In the Monte Carlo transport analysis, the MCNP code was used to estimate the neutron and gamma-ray doses and differential flux (in energy) spectra at ten locations within the CPRF. The complex geometry of the ZTH dictated that the problem be solved in a two-step process: First, a cylindrical surface source enclosing the ZTH was computed, and then this source was used as the radiation source for the CPRF building calculations. Using a source strength of 10{sup 15} neutrons, identical calculations were performed for both deuterium-deuterium and deuterium-tritium fusion plasmas.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.