Abstract
This study comprehensively compared two approaches for analyzing the shielding design of the proton therapy facility at China Medical University Hospital. The first approach essentially involved two approximate models: one for estimating the transmitted radiation through thick shields, and one for estimating radiation streaming at locations near a maze entrance. The second approach relied on Monte Carlo simulations for predicting the radiation field in a complex environment. A total of 22 beam loss scenarios were considered, and dose rates at 32 locations around the facility were estimated using the two approaches. The comparison results demonstrated that the simplified approach proposed in this study can yield fairly accurate or conservative estimates for quickly performing shielding design or dose assessment in a real-world proton therapy facility.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.