Abstract The pitch-to-diameter ratio (P/D) of the tube layout in shell-and-tube heat exchangers is one of the major parameters with which the designer may control heat transfer and pressure drop and facilitate mechanical cleaning. As part of a comprehensive investigation of waterflow-induced tube vibration in an industrial-size research heat exchanger, various configurations characterized by different design parameters, including P/D ratio, had been investigated. To provide a comparison with previous data obtained with P/D = 1.25, this paper presents the results of a study of eight different tube bundle configurations with P/D = 1.42. Four equilaterally spaced tube layout patterns and two baffle edge orientations were investigated. The results indicate that the greater flow area of the P/D = 1.42 configuration increases flow penetration into the bundle, reduces the tube-to-tube vibration coupling and generally provides less well-defined, even though sometimes improved, fluidelastic instability thresholds.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.