Abstract

AbstractA graphical method of analysis is presented for preliminary design of outrigger truss‐braced high‐rise shear wall structures with non‐fixed foundation conditions subject to horizontal loading. The method requires the calculation of six structural parameters: bending stiffness for the shear wall, bending and racking shear stiffnesses for the outrigger, an overall bending stiffness contribution from the exterior columns, and rotational stiffnesses for the shear wall and column foundations.The method of analysis employs a simple procedure for obtaining the optimum location of the outrigger up the height of the structure and a rapid assessment of the influence of the individual structural elements on the lateral deflections and bending moments of the high‐rise structure. It is concluded that all six stiffnesses should be included in the preliminary analysis of a proposed tall building structure as the optimum location of the outrigger as well as the reductions in horizontal deformations and internal forces in the structure can be significantly influenced by all the structural components. Copyright © 2004 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.