Abstract

In order to investigate the effect of the serviceshear load at the time of strengthening a thick slab using bonded transverse reinforcing bars, an experimental study has been carried out.Five (5)beams representing slices of a thick slab were tested to induce different shear load levels in the beamsat the time of strengthening then loaded up to shear failure. Tests were conducted on a slab without shear reinforcement and the others on slabs strengthened at two different load levels at the time of strengthening. The added shear reinforcement was distributed according to two different longitudinal spacings. The results show that,even in the presence of usual service loads, the shear strengthening of thick slabs with bondedbars offers a considerable increase in shear capacity compared to a thick slab without shear reinforcement.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.