Abstract

This article investigates the shear strength of steel plate reinforced concrete shear wall under cyclic loads. A nonlinear three-dimensional finite element model in ABAQUS was developed and validated against published experimental results. Then, a parametric study was conducted to evaluate the effects of the parameters on the lateral capacity of composite shear wall, including shear span ratio, concrete strength, axial load ratio, steel plate ratio and transverse reinforcement ratio of the web. Furthermore, a modified formula of shear strength of composite shear wall was proposed. Regression analyses were used to obtain the contribution coefficients of different parts from 720 finite element models. Finally, the shear strengths of specimens from published tests were compared with design strengths calculated using the proposed formula, American Institute of Steel Construction Provisions and Chinese Code. It was found that the Chinese Code well predicts the shear strength of composite shear wall of a steel plate ratio of less than 5%, while unsafely predicting that of a higher steel plate ratio. The American Institute of Steel Construction Provisions predictions are quite conservative because the contribution of the reinforced concrete is neglected. The modified formula safely predicts the shear strength of composite shear wall.