Abstract

The paper deals with the problem of evaluation of the panel zone (PZ) shear strength in beam-to-column connection. To this aim, the mechanical behaviour of the PZ and the European and American code provisions for the design of PZ are examined and critically discussed. Non-linear FEM analyses and experimental tests carried out on beam-to-column steel connections are also provided and compared with both European and American practices. Both numerical and experimental results have shown a good agreement with the American provisions. On the contrary, some drawbacks are identified in the application of European provisions, which cause overestimation of the PZ shear strength of about 50–60%. These differences could cause invalidation of the capacity design approach to the steel moment resisting frames, which in the case of European provisions should lead to strong panel zone, where the possibility of PZ yielding is precluded. Therefore, an improvement to the European code provisions is suggested in order to better evaluate the PZ shear strength.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.