Abstract
AbstractShear span-to-effective depth ratio (av/d) is known to affect the shear behavior of RC members. However, this effect has not been appropriately addressed in existing design guidelines for the fiber-reinforced polymer (FRP) strengthening of RC structures. This paper focuses on the effect of av/d on the behaviors of RC beams shear strengthened with full-wrapping FRP strips. A total of six strengthened beams and six normal beams are tested, with av/d ratios ranging from 1.0 to 3.5. The experimental results indicate that the FRP shear contribution increases initially with the av/d ratio, but decreases when the ratio is beyond 2.5. The FRP strain along the critical shear crack distributes in different manners for different av/d ratios. The authors’ experimental results and the test results from the literature are compared with predictions from available design guidelines. Although some recent design guidelines always provide a safe value, it can be overconservative. Conversely, other recent design guid...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.