Abstract

The present investigation addresses the shear strengthening of deficient reinforced concrete (RC) beams using carbon fiber-reinforced polymer (CFRP) sheets. The effect of the pattern and orientation of the strengthening fabric on the shear capacity of the strengthened beams were examined. Three beams with various lay-ups of strengthening fabric, 45°, 0°/90°, and 0°/90°/45° were examined, in addition to an unstrengthened control beam. Principal and shear strains were measured at different locations at the critical sections of the strengthened beams corresponding to each applied shear force. Experimental results showing the advantage of beam strengthened using the various lay-ups of CFRP sheets are discussed. It is concluded that Beam-45°, Beam-0°/90°, and Beam-0°/90°/45° show about 25%, 19%, and 40% increases in shear-load carrying capacity in comparison to the control beam, respectively. Also, there exists a critical value of shear force up to which there is no appreciable shear strain in the CFRP sheets/beam. This shear force marks the ultimate shear resistance of the control beam. However, the strengthened beams exhibited significant strength and stiffness even beyond the critical value of the shear force. A design example for shear strengthening shows that the design equations available in the literature underestimate the actual shear strength of the beams.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call